Technical Specifications
| Parameter | Specification |
|---|---|
| Connector A | MPO/APC Female (with pins) |
| Connector B | MPO/APC Female (without pins) |
| Fiber Type | OM3 50/125µm or OM4 50/125µm multimode |
| Fiber Count | 16 fibers |
| Cable Structure | Round trunk cable, tight-buffered |
| Cable Diameter | 3.0mm nominal |
| Jacket Rating | LSZH (OFNP, OFNR optional) |
| Jacket Color | Aqua (OM3), Erika Violet (OM4) |
| Operating Temperature | -20°C to +70°C |
| Storage Temperature | -40°C to +85°C |
| Minimum Bend Radius | 10× cable diameter (loaded), 20× (unloaded) |
Optical Performance
| Parameter | OM3 Specification | OM4 Specification |
|---|---|---|
| Insertion Loss (max) | ≤0.35 dB per mated pair | ≤0.35 dB per mated pair |
| Return Loss (min) | ≥60 dB (APC polish) | ≥60 dB (APC polish) |
| Fiber Attenuation | ≤3.0 dB/km @ 850nm | ≤3.0 dB/km @ 850nm |
| Bandwidth | ≥1500 MHz·km @ 850nm | ≥3500 MHz·km @ 850nm |
| Numerical Aperture | 0.200 ± 0.015 | 0.200 ± 0.015 |
Mechanical Specifications

Mechanical Durability
- Insertion/Extraction Cycles:500 cycles minimum per IEC 61300-2-26
- Connector Retention Force:≥20N minimum
- Cable Tensile Strength:100N for 1 minute
- Impact Resistance:1.5m drop test per IEC 60068-2-32
Environmental Performance
- Temperature Cycling:-40°C to +85°C, 10 cycles
- Humidity Resistance:95% RH, 40°C, 1000 hours
- Salt Spray:5% NaCl solution, 48 hours
- Abrasion Resistance:100 cycles with 5N force

Structure & Polarity Configuration

The MPO/APC 16-fiber cable assembly features a ruggedized round trunk design with tight-buffered multimode fibers encased in a flame-retardant LSZH jacket. Each MPO connector housing is precision-molded with integrated strain relief boot, protecting the fiber array from mechanical stress during installation and operation.
Connector Configuration
The standard configuration includes one MPO/APC female connector with removable metal guide pins (male) and one MPO/APC female connector without pins (female), enabling direct mating between assemblies or with panel-mount adapters.
Polarity Options
This 16-fiber assembly supports multiple polarity types to accommodate various parallel optics architectures:
Type A (Straight-through)
Type A (Straight-through)
Fiber position 1 on Connector A maps to position 1 on Connector B, commonly used with polarity-reversing cassettes or panels
Type B (Reversed/Flipped)
Fiber position 1 on Connector A maps to position 16 on Connector B, ideal for direct switch-to-switch connections in 40G/100G deployments
Type C (Pairs-flipped)
Adjacent fiber pairs are flipped, supporting specific transceiver requirements
APC Angle Orientation
The 8° angled endface is precisely aligned within the MPO ferrule, with a key-up/key-down orientation marker ensuring proper rotational alignment during mating, critical for maintaining the low back reflection performance of APC connections.
Key Benefits of APC Polish:
- Ultra-low back reflection (≥60dB)
- Minimized signal interference
- Improved signal integrity for high-speed applications
- Reduced crosstalk between adjacent fibers
- Enhanced reliability in analog video transmission

Application Scenarios

40G/100G Data Center Spine-Leaf Architecture
Connects QSFP+ and QSFP28 transceiver modules between spine and leaf switches, enabling high-bandwidth east-west traffic with 16-lane parallel optics.

High-Performance Computing (HPC) Clusters
Provides low-latency, high-bandwidth interconnects between compute nodes and storage arrays, supporting InfiniBand EDR/HDR and proprietary HPC fabrics.

Telecommunications Central Office
Links DWDM equipment, OTN switches, and fiber distribution frames in metro and long-haul networks where APC connectors are mandatory to minimize back reflections.

Broadcast and Video Production Facilities
Supports uncompressed 12G-SDI video transmission over fiber using parallel optics, where APC polish prevents reflections that could cause picture artifacts.

Cloud Service Provider Edge Data Centers
Enables scalable structured cabling systems with pre-configured polarity for rapid deployment of compute capacity, reducing installation time from hours to minutes per rack.

Structured Cabling System
Creates a scalable two-tier cabling system with permanent MPO trunks in pathways above the cold aisle, with shorter MPO jumpers and LC patch cords for equipment connections.
Typical Network Topology

In a structured cabling deployment, MPO/APC trunk cables form the horizontal backbone connecting patch panels at the main distribution area (MDA) to zone distribution areas (ZDA) within the data center.
At each endpoint, MPO-to-LC or MPO-to-LC APC cassettes or breakout modules convert the 16-fiber trunk into eight duplex LC ports for equipment connection.
This architecture minimizes cable congestion and simplifies moves-adds-changes, providing a flexible and scalable solution for high-density data center environments.
Factory Quality Assurance
3D Interferometric Endface Inspection
Insertion and Return Loss Testing at 850nm and 1300nm
Mechanical Durability Validation (500-cycle insertion/extraction)
Environmental Conditioning per IEC 61300-2 series
Comprehensive test reports with each assembly
Customization Options
We offer extensive customization to meet specific project requirements,
ensuring our MPO/APC cable assemblies perfectly fit your unique application needs.

Fiber & Connector Option
Fiber Types:OM3, OM4, OM5 (wideband multimode), OS2 (single-mode 9/125µm with APC)
Fiber Count:8, 12, 16, 24, 32, 48, 72, or 96 fibers in multiples of 4 or 12
Connector Polish:
UPC (standard physical contact) or APC (8° angled) on either or both ends
Pin Configuration:Male (with pins), female (without pins), or pinned on both ends with gender adapter
Connector Boot Color:Custom color-coding available for polarity identification or pathway designation

Cable Construction
Length Range:Standard 1m to 100m; extended lengths up to 300m available for campus backbone applications
Jacket Materials:LSZH (low smoke zero halogen), OFNP (plenum rated), OFNR (riser rated), PVC, or armored outdoor-rated
Cable Diameter:Standard 3.0mm round; microduct-compatible 2.0mm mini-cable; or flat ribbon cable
Jacket Color:Standard aqua (OM3), erika violet (OM4), lime green (OM5), yellow (OS2); custom colors available

Value-Added Services
Polarity Configuration:Factory-set Type A, B, or C polarity with verification documentation
Custom Labeling:Laser-etched or heat-shrink labels with customer-specified text, barcodes, or QR codes
Breakout Options:Hybrid assemblies combining MPO trunk on one end with fanned-out LC, SC, or ST duplex connectors
Packaging:Individual poly bags, coiled in cable boxes, or wound on reels; custom packaging available
Related Products & Accessories
To complete your MPO/APC fiber optic infrastructure, we offer a comprehensive ecosystem of compatible components designed for seamless integration.
MPO/MTP Cassette Modules
High-density adapter panels converting 16-fiber MPO to 8× duplex LC or SC ports, available in Type A/B/C polarity for plug-and-play connectivity.
MPO Fiber Distribution Units
1U and 2U rack-mount enclosures with sliding trays accommodating up to 144 fibers, featuring integrated MPO-to-MPO adapters and cable management.
MPO/APC Cleaning Tools
Specialized cleaning cassettes, swabs, and one-click cleaners designed for angled MPO endfaces, essential for maintaining low insertion loss.
MPO Loopback Modules
Precision optical loopbacks in various configurations for transceiver testing, network troubleshooting, and automated link verification.
MPO-to-LC Breakout Cables
Conversion cables with MPO/APC on trunk end and individual LC/APC duplex legs, ideal for connecting MPO infrastructure to legacy equipment.
Fiber Optic Enclosures
Wall-mount and rack-mount housings for secure MPO splice and interconnection points in backbone pathways.
Hot Tags: mtp/mpo cable-mpo/apc-mpo/apc-om3/om4-16 fibers, China mtp/mpo cable-mpo/apc-mpo/apc-om3/om4-16 fibers manufacturers, suppliers, factory