High-Density OS2 Fiber Solutions for Data Centers & Telecom Networks
MPO/MTP single mode fiber cables are pre-terminated optical assemblies engineered for high-density network architectures. Utilizing OS2 single mode fiber and multi-fiber connectors, these cables provide low-loss transmission for standard 40G, 100G, 400G, and 800G optical transceivers. Each assembly is factory-terminated and tested to reduce on-site installation time and ensure link budget compliance in enterprise and telecom infrastructures.
-
Low Loss OS2 MPO Fiber CableDimiFiber OS2 MPO trunk cables are factory-terminated optical assemblies designed for high-density data center backbone and campus infrastructure. Engineered for 40G, 100G, and 400G transmission,
-
MPO To LC Single Mode Fiber CableDimifiber MPO-LC patch cables provide high-density interconnects for the migration from MPO-based backbone cabling to LC-interface network equipment. Engineered for reliability in data centers and
-
MPO Single Mode Patch CordThe DimiFiber MPO Single Mode Patch Cord is engineered for high-density network infrastructure, including 40G/100G/200G/400G Ethernet environments. Designed for data centers and telecommunications
-
MPO Single Mode Trunk CableDimi MPO Trunk Cables are premium, factory-terminated fiber assemblies designed for rapid, reliable, and scalable network deployment. Engineered for modern high-speed infrastructure, our solution
-
OS2 MTP Single Mode Fiber CableThe OS2 MTP/MPO trunk cable is a high-density, pre-terminated fiber solution. It utilizes 9/125μm single-mode fiber to support high-bandwidth, long-distance signal transmission. The MTP/MPO interface
-
OS2 MPO Single Mode Fiber CableDimiFiber OS2 MPO/MTP trunk cables are engineered for high-density fiber interconnections in hyperscale data centers and telecommunication backbones. These cables utilize 9/125μm OS2 single-mode
Technical Performance

1. Optical Specifications
Standard Insertion Loss: Less than or equal to 0.35dB
Elite / Low Loss Insertion Loss: Less than or equal to 0.25dB (Recommended for tight 400G/800G link budgets)
Return Loss: Greater than or equal to 60dB (APC Polish)
2. Physical & Environmental Setup
Fiber Types: OS2 Single Mode (G.652.D / G.657.A1 / G.657.A2 bend-insensitive fiber)
Fiber Counts: 8-fiber, 12-fiber, 16-fiber, and 24-fiber configurations
Polarity Options: Type A (Straight), Type B (Cross), Type C (Pair Flip)
Operating Temperature: -20°C to +70°C
3. Flame Retardant Ratings & Compliance
We support global deployment regulations with verified jacket materials:
OFNP (Plenum): Standard for North American air plenum spaces.
LSZH (Low Smoke Zero Halogen): Standard for European data center safety.
OFNR (Riser): Standard for vertical shafts.
Compliance: Fully compliant with RoHS, REACH, CE, and UL testing.
Technical Specifications Table
|
Parameter |
Specification |
|
Fiber Type |
OS2 Single Mode (G.652.D / G.657.A1 / G.657.A2) |
|
Connector Type |
Standard MPO / MTP Compatible |
|
Fiber Count |
8F / 12F / 16F / 24F |
|
Wavelength |
1310nm / 1550nm |
|
Insertion Loss (IL) |
Standard: ≤0.35dB / Elite / Low Loss: ≤0.25dB |
|
Return Loss (RL) |
≥60dB (APC Polishing) |
|
Polarity |
Type A / Type B / Type C |
|
Jacket Material |
LSZH / OFNP / OFNR / PVC |
|
Operating Temperature |
-20°C to +70°C |
|
Standards Compliance |
Telcordia GR-1435-CORE, IEC 61754-7, TIA-604-5, RoHS, REACH |
Quality Control & Verification
Every patch cord undergoes a 100% factory verification process before shipping. Test documentation is generated for each production batch.

End-Face Geometry
Microscopic inspection is performed to confirm zero scratches, pits, or contamination on the ferrule surface.
3D Interferometer Testing
Verification of fiber height, radius of curvature, and apex offset according to Telcordia GR-326 standards.


Optical Measurement
Verification of Insertion Loss (IL) and Return Loss (RL) at 1310nm and 1550nm.
Polarity Mapping
Hardware check to ensure fiber channels match the specified wiring type (A/B/C).

Custom Manufacturing Options
As an OEM/ODM manufacturer, we supply tailored assemblies based on project layouts:
Connectors
Standard MPO or high-performance MTP compatible connectors (Male with pins / Female without pins).
Cable Construction
2.0mm/3.0mm Round, Flat Ribbon, or High-Density Micro-cable.
Breakout Styles
Customized breakout lengths and staggered leg designs for specific switch patch panels.
Packaging
Serialized tracking labels, custom barcoding, and neutral packaging for distributors.
FAQ
As one of the most professional mpo/mtp single mode fiber cable manufacturers and suppliers in China, we're featured by quality products and good service. Please rest assured to wholesale custom made mpo/mtp single mode fiber cable from our factory.