MPO To SC Breakout Cable-OM4-8/12
Details
Key Specifications
Connector Type: MPO Female to SC/UPC Duplex (breakout configuration)
Fiber Type: OM4 50/125µm laser-optimized multimode fiber
Fiber Count: 8-fiber or 12-fiber configurations available
Jacket Rating: LSZH (Low Smoke Zero Halogen), OFNP and PVC options
Length Range: 1m to 100m, custom lengths available
Application: High-speed 40G/100G data center interconnects
Category
MTP MPO Fiber Breakout Cable
Share to
Description

OM4 MPO to SC Breakout Cable for SC Duplex Distribution

 

8 fiber OM4 MPO to SC breakout cable with SC connectors

DIMI OM4 MPO to SC breakout cables connect an MPO/MTP female end to SC/UPC duplex ports in structured fiber installations. The 8-fiber assembly ends in four SC duplex pairs; the 12-fiber version ends in six pairs. Both use OM4 50/125 µm multimode fiber with factory-terminated connectors.

These pre-terminated MPO-to-SC harnesses are intended for networks that use an MPO distribution route but still need individual SC connections at the patch field. Buyers can select the fiber count, trunk length, fanout length and cable jacket around the actual panel arrangement.

Request DIMI OM4 Breakout Cable Pricing

 

8F and 12F MPO to SC Fanout Configurations

 

Choose 8F for four duplex SC ports. Eight active fiber paths terminate in eight individual SC/UPC plugs, arranged in four duplex pairs. It suits a panel layout that requires four paired SC connections.

Choose 12F for six duplex SC ports. All twelve fibers terminate in twelve individual SC/UPC plugs. For either version, the MPO mating arrangement and fiber polarity must match the installed distribution equipment; fiber count does not by itself define the connector housing or Tx/Rx map.

DIMI offers both OM4 fanout configurations for project orders, so the port count and branch arrangement can follow the approved panel layout.

OM4 MPO to SC breakout cable with multiple SC fanout connectors

 

OM4 MPO to SC Breakout Cable Specifications

 

Specification Available configuration
Fiber type OM4 50/125 µm multimode
Fiber counts 8F or 12F
MPO end MPO/MTP female
SC termination 8F: 4× SC Duplex UPC (8 plugs); 12F: 6× SC Duplex UPC (12 plugs)
Construction Round trunk with breakout fanout
Trunk diameter 3.0 mm nominal
Main cable length 1–100 m, with custom lengths
Fanout length 0.5 m, 1.0 m or custom
Jacket choices LSZH standard; OFNP or PVC options
Standard OM4 jacket color Erika violet
Operating temperature −20°C to +70°C
MPO insertion loss ≤0.35 dB typical; ≤0.50 dB maximum
SC insertion loss ≤0.30 dB typical; ≤0.50 dB maximum
OM4 attenuation at 850 nm ≤2.3 dB/km
OM4 attenuation at 1300 nm ≤0.6 dB/km
Modal bandwidth at 850 nm ≥4700 MHz·km

 

The MPO and SC loss limits are specified separately. For a link budget, use the published maximum connector limits alongside the fiber run and any other mated connections, rather than treating one connector value as the loss of the completed channel.

 

Pre-Terminated MPO to SC Cables for Existing Patch Fields

 

A single MPO feed can be distributed to existing SC adapter ports without terminating each fiber at the installation site. The 8F OM4 MPO-to-SC cable provides eight SC plugs; the 12F configuration serves a larger six-duplex-port patch field.

For a retrofit or new row build, this arrangement keeps the equipment-side SC format while using a multi-fiber upstream connection. DIMI can supply the breakout length specified for the rack layout and the selected jacket for the cable pathway.

Where another output connector is needed, the MPO breakout cable range covers alternative termination formats.

OM4 fiber connections at SC duplex patch panel

 

Applications for OM4 MPO to SC Fanout Assemblies
SC Patch Panel Upgrades
Keep existing SC adapter fields in service while bringing individual fiber connections from an MPO distribution point.
Equipment Row Distribution
Fan out a multi-fiber OM4 route to separate SC ports in a rack or intermediate distribution area.
Repeat OEM Builds
Use one agreed fiber count, port layout and fanout length across identical panels or staged installations.

 

Custom MPO to SC Breakout Cable Orders for OEM Projects

 

DIMI supplies custom OM4 MPO to SC breakout assemblies for repeat panel builds, rack installations and OEM cabling projects. Main cable lengths are listed from 1 to 100 m; SC fanout legs can be 0.5 m, 1.0 m or made to the project arrangement.

LSZH is the standard jacket option, with OFNP or PVC alternatives available. SC branch identification and the required MPO-to-SC mapping can be specified against the approved configuration, giving buyers a consistent basis for repeat purchasing.

For a bulk MPO-to-SC cable quotation, provide the 8F or 12F version, SC port layout, cable and leg lengths, jacket choice and quantity. This allows pricing against the assembly actually needed on site.

Get DIMI Custom Harness Pricing

OM4 MPO to SC cable assembly on a production workbench

 

Connector Inspection and Optical Tests for MPO to SC Assemblies

 

Fiber optic inspection microscope used for connector inspection

DIMI inspects connector end faces, measures insertion and return loss, and checks fiber polarity and continuity as part of production testing. The inspection process includes 3D geometry measurement, with separate published insertion-loss limits for the MPO and SC ends.

For project acceptance, test reports are available on request. Inspection records and the approved fiber map can be included in the procurement requirements when several panels or repeat batches must use the same configuration.

 

OM4 MPO to SC Breakout Cable Procurement FAQs

 

How many SC connections are supplied with an 8F or 12F cable?

The 8F version has eight individual SC/UPC plugs arranged into four duplex pairs. The 12F version has twelve individual plugs arranged into six duplex pairs.

Does an 8-fiber MPO breakout specify the exact MPO housing and polarity?

No. Eight active fibers identify the fiber count, not every physical interface detail. The MPO mating connection and Tx/Rx polarity need to suit the installed panel and port mapping.

Are the MPO and SC insertion-loss limits the same?

No. The MPO end is specified at ≤0.35 dB typical and ≤0.50 dB maximum; the SC end is ≤0.30 dB typical and ≤0.50 dB maximum. These are connector-end figures, not an installed link guarantee.

Can the cable connect directly to any 40G or 100G optical transceiver?

Not automatically. The breakout terminates in SC/UPC connectors, so the equipment-side interface and fiber mapping must match the destination connection. An advertised speed alone does not establish compatibility.

Does DIMI offer customized MPO-to-SC cable lengths for repeat orders?

Yes. DIMI lists 1–100 m main cable lengths, 0.5 m or 1.0 m fanout legs and custom length options. LSZH, OFNP and PVC jackets are also available for project specifications.

 

modular-1

Get a DIMI OM4 MPO to SC Cable Quote

Order the 8F OM4 MPO-to-4-SC-duplex harness or the 12F OM4 MPO-to-6-SC-duplex version for your patch-panel layout. DIMI can prepare project pricing for the selected connector arrangement, cable length, fanout, jacket and order quantity.

Need a different SC interface arrangement? The MPO to SC adapter cable is a separate product option.

 